3
0
mirror of https://git.kernel.org/pub/scm/network/wireless/iwd.git synced 2024-11-27 11:39:23 +01:00
iwd/autotests/util/ead.py
James Prestwood e2aca6e917 auto-t: correctly import Mapping from collections
The current way this was being done was to import collections and
use collections.Mapping. This has been deprecated since python 3.3
but has worked up until python 3.10. After python 3.10 this will
no longer work, and Mapping must be imported from collections.abc.
2022-06-01 11:01:50 -05:00

106 lines
3.2 KiB
Python

#!/usr/bin/python3
from gi.repository import GLib
import dbus
import time
import iwd
from collections.abc import Mapping
from config import ctx
EAD_SERVICE = 'net.connman.ead'
EAD_ADAPTER_INTERFACE = 'net.connman.ead.Adapter'
DBUS_OBJECT_MANAGER = 'org.freedesktop.DBus.ObjectManager'
DBUS_PROPERTIES = 'org.freedesktop.DBus.Properties'
EAD_TOP_LEVEL_PATH = '/'
class Adapter(iwd.IWDDBusAbstract):
_iface_name = "net.connman.ead.Adapter"
@property
def name(self):
return self._properties['Name']
@property
def address(self):
return self._properties['Address']
@property
def active(self):
return self._properties['Active']
@property
def connected(self):
return self._properties['Connected']
@property
def authenticated(self):
return self._properties['Authenticated']
class AdapterList(Mapping):
def __init__(self, ead):
self._dict = {}
ead._object_manager.connect_to_signal("InterfacesAdded",
self._interfaces_added_handler)
ead._object_manager.connect_to_signal("InterfacesRemoved",
self._interfaces_removed_handler)
objects = ead._object_manager.GetManagedObjects()
for path in objects:
for interface in objects[path]:
if interface == EAD_ADAPTER_INTERFACE:
self._dict[path] = Adapter(path, objects[path][interface], service=EAD_SERVICE)
def __getitem__(self, key):
return self._dict.__getitem__(key)
def __iter__(self):
return self._dict.__iter__()
def __len__(self):
return self._dict.__len__()
def __delitem__(self, key):
self._dict.pop(key).remove()
def _interfaces_added_handler(self, path, interfaces):
if EAD_ADAPTER_INTERFACE in interfaces:
self._dict[path] = Adapter(path, interfaces[EAD_ADAPTER_INTERFACE], service=EAD_SERVICE)
def _interfaces_removed_handler(self, path, interfaces):
if EAD_ADAPTER_INTERFACE in interfaces:
del self._dict[path]
class EAD(iwd.AsyncOpAbstract):
_bus = ctx.get_bus()
_object_manager_if = None
_adapters = None
def __init__(self):
ctx.non_block_wait(self._bus.name_has_owner, 20, EAD_SERVICE,
exception=TimeoutError('EAD has failed to start'))
self._adapters = AdapterList(self)
@property
def _object_manager(self):
if self._object_manager_if is None:
self._object_manager_if = \
dbus.Interface(self._bus.get_object(EAD_SERVICE,
EAD_TOP_LEVEL_PATH),
DBUS_OBJECT_MANAGER)
return self._object_manager_if
def list_adapters(self, wait_to_appear = 0, max_wait = 50):
if not wait_to_appear:
return list(self._adapters.values())
ctx.non_block_wait(lambda s, num : len(s._adapters) >= num, max_wait, self, wait_to_appear,
exception=TimeoutError('EAD has no associated devices'))
return list(self._adapters.values())