We use the load_settings method to bootstrap the internal state of the
EAP WSC state machine. We require certain information to be provided by
the higher layers, namely:
Global Device parameters
- Manufacturer
- Model Name
- Model Number
- Serial Number
- Device Name
- Primary Device Type
- OS Version
Session specific parameters
- MAC Address
- Configuration Methods
- RF Bands
The following parameters are auto-generated for each new session, but
can be over-ridden if desired
- Private Key
- Enrollee Nonce