3
0
mirror of https://git.kernel.org/pub/scm/network/wireless/iwd.git synced 2024-11-05 11:39:24 +01:00
Commit Graph

4304 Commits

Author SHA1 Message Date
James Prestwood
6088c06507 ie: add parser/builder for hotspot indication element
The parser fully parses the IE and returns the version, Domain ID,
and PPS MO ID. This is meant to be used with an IE in scan results.

The builder only takes the version number, and assumes DGAF disabled,
and no Domain ID or PPS MO ID.
2019-07-24 00:13:27 -05:00
Tim Kourt
34800bfa63 client: Enable word completion for the SSIDs with spaces
"I--> results in "IWD 1"
2019-07-23 17:20:39 -05:00
Tim Kourt
9736bc211c auto-t: Test disconnect on connect while connected 2019-07-23 17:19:12 -05:00
Tim Kourt
5478034eb7 network: Check for already connected network
Check if the requested network is already connected,
if so return success.
2019-07-23 17:19:12 -05:00
Tim Kourt
d0ee923dda station: Disconnect, if needed, on a new connection attempt
Previously, iwd used to throw net.connman.iwd.Busy when connection
attempt was made while connected. The new behavior allows iwd to
seamlessly disconnect from the connected network and attempt a new
connection.
2019-07-23 17:19:12 -05:00
Denis Kenzior
60078478cf monitor: Dump RTM_NEWROUTE/DELROUTE/GETROUTE 2019-07-23 11:35:27 -05:00
Denis Kenzior
c439a2614c monitor: Dump IFLA_LINKINFO 2019-07-23 09:31:05 -05:00
Denis Kenzior
45dfd26689 monitor: Supported nested rtnl attributes 2019-07-23 09:30:42 -05:00
Denis Kenzior
c47fee2e78 monitor: Print string length of rtnl attributes 2019-07-23 09:22:57 -05:00
Denis Kenzior
140c626a4b monitor: Remove duplicate monitor_interface structure
The global structure was intended to be used, not the one local to the
main function.
2019-07-23 09:22:01 -05:00
Denis Kenzior
45ce4bc8eb monitor: Fix printing of nlmsgerr netlink messages 2019-07-23 08:21:51 -05:00
Denis Kenzior
e0eb824fe3 monitor: nlmsg attributes are unsigned 2019-07-23 07:41:53 -05:00
Denis Kenzior
d63f73adf9 monitor: Generalize flag printing 2019-07-23 07:24:20 -05:00
James Prestwood
55491f5c02 network: add boolean for hs20 support
Since NAI realms, Roaming Consortium and HESSID are defined in 802.11,
they are not a guarentee that the network is Hotspot 2.0. The indication
element in addition to these IE's gives a better idea of Hotspot 2.0
support. Now, when a BSS is added this is_hs20 boolean will get set to
true if the HS20 IE was found in the BSS.

Now, if is_hs20 is set AND one of NAI realms, roaming consortium, or
HESSID is set we know this is a hotspot 2.0 network.
2019-07-21 15:17:05 -05:00
Denis Kenzior
46b85c00c1 netconfig: Use uint32 instead of unsigned int
For consistency, the type used to obtain the new length should be the
same as the passed in len parameter, which is uint32_t
2019-07-21 07:06:17 -05:00
Denis Kenzior
d8c058f25f netconfig: Use uint32_t len instead of int 2019-07-21 07:05:51 -05:00
Tim Kourt
18119537f7 netconfig: Unify static and dynamic addressing APIs 2019-07-21 07:05:15 -05:00
Tim Kourt
2d007a25b6 netconfig: Differentiate the origin of the addresses.
The origin of the addresses is later used with the route
installations for the convenience of the user.
2019-07-21 07:05:14 -05:00
Tim Kourt
1c7e803dbb rtnlutil: Add utility to DUMP ipv4 routes 2019-07-21 07:04:32 -05:00
Tim Kourt
83db65e929 rtnlutil: Add utility to extract route attributes 2019-07-20 06:51:46 -05:00
Tim Kourt
56670755c1 netconfig: Refactor rtnl error handling
Keep the rtnl destruction code in one place as it will have a
few more usages in the future.
2019-07-20 05:53:15 -05:00
Tim Kourt
f1dd6b1084 client: Fix network name completion after restart of iwd
Previously, on service disappeared event the list of the known
proxy objects was cleared, but pointers to the default entity
per command family wasn’t reset. Reset default entities for
the command families to remove the dead pointers to the deleted
proxy objects.

==1325== Invalid read of size 8
==1325==    at 0x4055D4: proxy_interface_is_same (dbus-proxy.c:439)
==1325==    by 0x407C28: match_by_partial_name (network.c:220)
==1325==    by 0x40547C: proxy_interface_find_all (dbus-proxy.c:424)
==1325==    by 0x405592: proxy_property_str_completion (dbus-proxy.c:153)
==1325==    by 0x407DA9: network_name_completion (network.c:241)
==1325==    by 0x4E596D5: rl_completion_matches (in /usr/lib64/libreadline.so.7.0)
2019-07-18 23:37:54 -05:00
James Prestwood
fd1a267313 scan: free hs20_ie 2019-07-18 23:35:35 -05:00
James Prestwood
0241fe81df sae: check minimum anti-clogging token size
It is possible for a zero-length anti-clogging token payload to cause
IWD to abort. If the length passed into sae_process_anti_clogging was
1, l_memdup would be called with a size of -1. This will cause malloc
to abort.

Fix this by checking for a minimum packet length and dropping the
packet if the length is too small.
2019-07-18 23:34:03 -05:00
Denis Kenzior
fe3858f738 station: Fix typo 2019-07-17 09:00:39 -05:00
James Prestwood
3c27528523 scan: station: add HS20 indication element to (Re)Association
The HS20 indication element should always be included during
(Re)Association per the spec. This removes the need for a
dedicated boolean, and now the hs20_ie can be used instead.
2019-07-16 21:14:41 -05:00
Denis Kenzior
4948bfac20 station: Add support for ProtocolVersion
ProtocolVersion in the EAPoL group can be used to force a particular
EAPoL version if the RADIUS server on a given network requires it
2019-07-16 12:00:45 -05:00
James Prestwood
a1699b1587 hotspot: add length check for roaming consortium
The hotspot spec specifically mentions the roaming consortium OI be
3 or 5 bytes long. This requirement also prevents potential buffer
overflows if the user were to configure a long roaming consortium OI.
2019-07-16 12:00:35 -05:00
Denis Kenzior
0f6d1ece78 eapol: Remove eapol_sm_set_protocol_version
Handshake state will now pick reasonable defaults
2019-07-15 21:45:58 -05:00
Denis Kenzior
483194ee91 unit: Update to the new handshake_state API 2019-07-15 21:45:32 -05:00
Denis Kenzior
d984c605f7 handshake: Add handshake_state_set_protocol_version 2019-07-15 21:45:12 -05:00
Denis Kenzior
f7e23b3512 eapolutil: Add 2010 EAP protocol version 2019-07-15 21:24:05 -05:00
Denis Kenzior
7ba4f53c57 scan: Make sure to reset triggered for aborted scans
If the scan was triggered and later aborted, make sure to reset the
triggered value when the CMD_NEW_SCAN_RESULTS event comes in.

src/station.c:station_enter_state() Old State: disconnected, new state: connecting
src/scan.c:scan_notify() Scan notification 33
src/station.c:station_netdev_event() Associating
src/scan.c:scan_notify() Scan notification 34
Aborting (signal 11) [/home/denkenz/iwd-master/src/iwd]
++++++++ backtrace ++++++++
 #0  0x7efd4d6a2ef0 in /lib64/libc.so.6
 #1  0x42b20d in scan_notify() at src/scan.c:1383
2019-07-15 15:58:03 -05:00
Denis Kenzior
5ff23af29e scan: Add extra scan_cancel debugs 2019-07-15 14:53:47 -05:00
James Prestwood
2b12759595 monitor: basic ANQP printing
Simply prints the ANQP ID (human readable) and the length. Once
the ANQP dependency on netdev is removed the full ANQP parser
can be used, but for now its done manually. Once this is done it
will be much easier to print the actual ANQP ID data.
2019-07-15 14:53:47 -05:00
James Prestwood
2c19085ccd anqp: move ANQP parsers into anqputil
This allows monitor to use the ANQP parser utils without depending
on netdev.
2019-07-15 14:53:44 -05:00
Tim Kourt
6efc94ff5a resolve: Fix message argument
Previously, the argument was incorrectly passed by reference
instead of by value.
2019-07-15 14:06:26 -05:00
Denis Kenzior
f557c7e6cd treewide: Use nl80211cmd_to_string
Using integer ids for event notifications received was hard to debug.
Use the nl80211cmd_to_string function to prettify these.
2019-07-15 14:06:26 -05:00
Denis Kenzior
7f0b169e71 monitor: Use nl80211cmd_to_string 2019-07-15 14:06:26 -05:00
Denis Kenzior
bb61e971e5 nl80211cmd: Introduce new utility 2019-07-15 14:06:26 -05:00
James Prestwood
b483a78464 monitor: update nlmon.c to use exposed vendor OUIs 2019-07-15 12:42:34 -05:00
James Prestwood
090ac03100 ie: expose vendor OUIs
In the same fashion as the WSC WFA OUI, ie.[ch] will now expose the
other vendor OUIs to avoid duplication across multiple files in IWD
as well as used in iwmon.
2019-07-15 12:42:22 -05:00
Andrew Zaborowski
213d75b9bb scan: Process P2P IEs from scan results 2019-07-15 12:40:44 -05:00
Andrew Zaborowski
cf684fdfa1 scan: Add option to use the NO_CCK scan flag
P2P probe requests are to be sent at min 6.0 Mb/s using OFDM,
specifically the 802.11b rates are prohibited (section 2.4.1 in Wi-Fi
P2p Technical Spec v1.7), some of which use CCK modulation.  This is
already the default for 5G but for 2.4G the drivers generally do this
if we set the NL80211_ATTR_TX_NO_CCK_RATE flags with
NL80211_CMD_TRIGGER_SCAN.
2019-07-15 11:36:34 -05:00
Andrew Zaborowski
2a5c2cec46 monitor: Print "None" for empty p2p flags 2019-07-15 11:30:44 -05:00
James Prestwood
ce9e61d727 auto-t: hotspot dir not hidden 2019-07-15 11:14:01 -05:00
James Prestwood
85131f4827 hotspot: make hotspot dir not hidden 2019-07-15 11:13:55 -05:00
James Prestwood
c5eba1cc27 auto-t: add test for Hotspot with roaming consortium 2019-07-15 11:11:29 -05:00
James Prestwood
8bcb8e870e ie: fix incorrect length check for hotspot indication
The length check was incorrectly assuming that PPS MO ID or
ANQP Domain ID would be present in the IE. Both these are optional
and without then the minimum length is 5 bytes, not 7.
2019-07-12 18:51:57 -05:00
James Prestwood
993d9cbf6b station: check hs20_capable first before ANQP
If a BSS is not a hotspot 2.0 BSS then there is no reason to bother
checking configuration files.
2019-07-12 18:51:36 -05:00