This moves all the de-init code into kill(), which fixes a few
reference issues causing processes to hang around longer than
desired. If the process terminates on its own and/or the last
reference is lost __del__ will kill the process and clean up.
There were a few issues with the cleanup of Hostapd. First the
process was only being killed, which did not actually remove
the process from the list.
In addition, with EAP-SIM/AKA tests, hostapd created sim_db
unix socket files which it does not clean up.
This is somewhat of an open issue/TODO but for now this avoids
the exception caused by trying to remove a radio that has been
moved to a namespace. Once a radio is moved hwsim loses that phy
and can no longer interact with it. This causes the Destroy()
method call to fail.
A cleanup parameter was added to __init__ which can be used
by processes which create any additional files or require more
a custom cleanup routine. Some additional house keeping was
done to make Process cleanup more robust.
Though multi-test processes seemed like a good idea in terms of
efficiency, the additional code/special cases was not worth it
for the only two multi-test processes (dbus/haveged). Intead this
concept was removed completely and TestContext/Namespaces will
now start all processes for each individual test. This also is
fair to all tests as a previous failed test could end up bleeding
into future tests.
Printing out processes was done manually but instead we can
make Process printing extendable by adding its own __str__
method. This now will print if the process is a multi-test
process as well.
Output files in namespaces were not handled differently and would
end up overwriting/duplicating files from the root namespace. These
are now named /tmp/<process>-<namespace>-out.
The process class was quite hard to understand, and somewhat
fragile when multiple output options were needed like verbose
and logging, and in some cases even an additional output file.
To make things simpler we can have all processes output to a
temporary file (/tmp/<name>-out) and set a GLib IO watch on
that file. When the IO watch callback fires any additional
files (stdout, log files, output files) can be written to.
For wait=True processes we do not use an IO watch, but do
the same thing once the process exits, write to any additional
output files using the process output we already have.
The log dir was never being cleaned out prior to a new logging
test run. This could leave old stale files around. Note that this
will remove any past log files so if you need them, you want to
make a copy before running test-runner with --log again.
Dbus should be started as a multi-test process from the
TestContext, which leaves the dbus address file around for
the full test run. For Namespaces dbus-daemon should be
closed when the Namespace closes.
There were some major problems related to logging and process
output. Tests which required output from start_process would
break if used with '--log/--verbose'. This is because we relied
on 'communicate' to retrieve the process output, but Popen does
not store process output when stdout/stderr are anything other
than PIPE.
Intead, in the case of logging or outfiles, we can simply read
from the file we just wrote to.
For an explicit --verbose application we must handle things
slightly different. A keyword argument was added to Process,
'need_out' which will ensure the process output is kept
regardless of --log or --verbose.
Now a user should be able to use --log/--verbose without any
tests failing.
The verbose arguments come in from the QEMU command line as a
single string. This should have been split into an array immediately
but was not. This led to issues like hostapd debug being enabled
when "-v hostapd_cli" was passed in.
Since the list of files copied to /tmp was part of the return value from
pre_test(), if an exception occurred inside pre_test(), "copied" would
be undefined and the post_test(ctx, copied) call in the finally clause
cause another exception:
raceback (most recent call last):
File "/home/balrog/repos/iwd/tools/test-runner", line 1508, in <module>
run_tests()
File "/home/balrog/repos/iwd/tools/test-runner", line 1242, in run_tests
run_auto_tests(config.ctx, args)
File "/home/balrog/repos/iwd/tools/test-runner", line 1166, in run_auto_tests
post_test(ctx, copied)
UnboundLocalError: local variable 'copied' referenced before assignment
(apart from not being able to clean up the files). Pass "copied" as a
paremeter to pre_test instead.
Use the hwsim DBus API rather than command line. This both is
faster and more dynamic than doing so with the command line.
This also avoids tracking the radio ID since we can just hang
on to the radio Dbus object directly.
For better reliability the processor count is now set to qemu.
In cases of low CPU count (< 2) hosts the processor count is
limited to 1. Otherwise half of the host cores will be used for
the VM.
Allow the storage directory (default /tmp/iwd) to be configured
just like the state directory. This is in order to support multiple
IWD instances which require separate storage directories for network
provisioning files.
Our simulated environment was really only meant to test air-to-air
communication by using mac80211_hwsim. Protocols like DHCP use IP
communication which starts to fall apart when using hwsim radios.
Mainly unicast sockets do not work since there is no underlying
network infrastructure.
In order to simulate a more realistic environment network namespaces
are introduced in this patch. This allows wireless phy's to be added
to a network namespace and unique IWD instances manage those phys.
This is done automatically when 'NameSpaces' entries are configured
in hw.conf:
[SETUP]
num_radios=2
[NameSpaces]
ns0=rad1,...
This will create a namespace named ns0, and add rad1 to that
namespace. rad1 will not appear as a phy in what's being called the
'root' namespace (the default namespace).
As far as a test is concerned you can create a new IWD() class and
pass the namespace in. This will start a new IWD instance in that
namespace:
ns0 = ctx.get_namespace('ns0')
wd_ns0 = IWD(start_iwd=True, namespace=ns0)
'wd_ns0' can now be used to interact with IWD in that namespace, just
like any other IWD class object.
Sometimes improperly written tests can end up causing future tests
to fail. For faster debugging you can now add a '+' after a given
autotest which will start that test and run all tests which come
alphabetically after it (as if you are running a full autotest suite).
Example:
./test-runner -A testWPA+
This will run testWPA, testWPA2, testWPA2-no-CCMP, testWPA2-SHA256,
and testWPA2withMFP.
This can result in strange test results since there was no less
than zero checks before subtracting the total tests from failed
tests. In case of an internal exception we can just set all values
to zero. This will be handled specially as we do for timeout
errors.
You can now specify a limited list of subtests to run out of a
full auto-test using --sub-tests,-S. This option is limited in
that it is only meant to be used with a single autotest (since
it doesn't make much sense otherwise).
The subtest can be specified both with or without the file
extension.
Example usage:
./test-runner -A testAP -S failure_test,dhcp_test.py
This will only run the two subtests and exclude any other *.py
tests present in the test directory.
Code was added with commit 04487f575b which passes a radio object
to the Interface class constructor and stores it in the Interface
object. The radio class also stores each Interface object which
creates a circular reference and causes the Radio to stick around
long after the tests finishes.
I cannot see why the Interface needs to keep track of the Radio
object. None of the wpa_supplicant utilities use this so it has
been removed.
Add support for a WPA_SUPPLICANT section in hw.conf where
'radN=<config_path>' lines will only reserve radios and create
interfaces for the autotest to be able to start wpa_supplicant on them,
i.e. this prevents iwd or hostapd from being started on them but doesn't
start a wpa_supplicant instance by itself.
The host systems configuration directories for IWD/EAD were
being mounted in the virtual machine. This required that the
host create these directories before hand. Instead we can
just set up the system and IWD/EAD to use directories in /tmp
that we create when we start the VM. This avoids the need for
any host configuration.
Allow the "hwsim_medium=no" setting in hw.conf's SETUP section to
disable starting hwsim. It looks like the packets going through
userspace add enough latency that active scans don't work, probe
responses don't arrive within the "dwell time" or probe requests are not
ACKed on time. I've tried modifying tools/hwsim.c to respond with the
HWSIM_CMD_TX_INFO_FRAME cmd as the first thing after receiving a
HWSIM_CMD_FRAME and even skipping the queue in ell/genl.c by writing the
command synchronously, but neither helped enough to make the scans work.
This does not rule out that hwsim or the way our scans are done can be
fixed and that would obviously be better than what I did in this patch.
This extends test-runner to also use iwmon if --log is enabled.
For this case the iwmon log will be found inside each test
log directory.
A new option, --monitor <file> was added in case full logging isn't
desired (potentially for timing issues) but a iwmon log is needed.
Be aware that when --monitor is used test-runner will mount the
entire parent directory. test-runner itself will only write to the
file specified, but just know that the parent directory is available
as read-write inside the VM.
--log takes precedence over --monitor, meaning the iwmon log will
be written to <logdir>/<test>/iwmon instead of the file specified
with --monitor if both options are provided.
The virtual environment changed slightly adding two network adatpers
which are connected to the same backend so they can communicate with
each other (basically connected to a switch). The hostapd command
line was modified to allow no interfaces to be passed in which lets
us create zero radios but still specify a radius_config file.
This is just a more concise/pythonic way of doing function arguments.
Since Process/start_process have basically the same argument names
we can simplify and use **kwargs which will pass the named arguments
directly to Process(). This also allows us to add arguments to Process
without touching start_process if we need.
Slower systems may not be able to make some timeouts that tests
mandated. All timeouts were increased significantly to allow tests
to pass on slow systems.
Removed test-runner.c, and renamed py_runner to test-runner. Removed
tools/test-runner from .gitignore.
This was done as a separate commit to avoid a nasty diff between the
existing test runner, and the new python version