This addresses the TODO where HostapdCLI was creating separate
objects each time HostapdCLI was called. This was worked around
by manually setting the important members but instead the class
can be re-worked to act as somewhat of a singleton, per-config
at least.
If there is no HostapdCLI instance for a given config one is
created and initialized. Subsequent HostapdCLI calls (for the
same config) will be returned the same object rather than a
new one.
get_ordered_network() now scans automatically and has been updated
to use the StationDebug.Scan() API rather than doing a full
dbus scan (unless full_scan = True). The frequencies to be scanned
are picked automatically based on the current hostapd status
(hidden behind ctx.hostapd.get_frequency()).
There is a common block of code in nearly every test which is incorrect,
most likely a copy-paste from long ago. It goes something like:
wd.wait_for_object_condition(device, 'not obj.scanning')
device.scan()
wd.wait_for_object_condition(device, 'not obj.scanning')
network = device.get_ordered_network("ssid")
The problem here is that sometimes the scanning property does not get
updated fast enough before device.scan() returns, meaning get_ordered_network
comes up with nothing. Some tests pass scan_if_needed=True which 'fixes'
this but ends up re-scanning after the original scan finishes.
To put this to rest scan_if_needed is now defaulted to True, and no
explicit scan should be needed.
This will use the Roam() developer method to force a roam to
a certain BSS. This is particularly useful for any test requiring
roams that are not testing IWD's BSS selection logic. Rather than
creating hwsim rules, setting low RSSI values, and waiting for the
roam logic/scan to happen Roam() can be used to force the roam
logic immediately.
Several tests tests for connectivity with the expectation that it
will fail. This ends up taking 30+ seconds because testutil retries
3 times, each with a 10 second timeout. By passing expect_fail=True
this lowers the timeout to zero, and skips any retries.
Break up the SAE tests into two parts: testSAE and testSAE-AntiClogging
testSAE is simplified to only use two radios and a single phy managed
by hostapd. hostapd configurations are changed via the new 'set_value'
method added to hostapd utils. This allows forcing hostapd to use a
particular sae group set, or force hostapd to use SAE H2E/Hunting and
Pecking Loop for key derivation. A separate test for IKE Group 20 is no
longer required and is folded into connection_test.py
testSAE-AntiClogging is added with an environment for 5 radios instead
of 7, again with hostapd running on a single phy. 'sae_pwe' is used to
force hostapd to use SAE H2E or Hunting and Pecking for key derivation.
Both Anti-Clogging protocol variants are thus tested.
main.conf is added to both directories to force scan randomization off.
This seems to be required for hostapd to work properly on hwsim.
This is similar to wait_for_object_condition, but will not allow
any intermediate state changes between the initial and expected
conditions. This is useful for roaming tests when the expected
state change is 'connected' --> 'roaming' with no changes in
between.
Sometimes scan results can come in with a MAC address which
should be in the first index of addrs[] (42:xx:xx:xx:xx:xx).
This causes a failure to lookup the radio path.
There was also a failure path added if the radio cannot be
found rather than rely on DBus to fail with a None path.
The arguments to SendFrame were also changed to use the
ByteArray DBus type rather than python's internal bytearray.
This shouldn't have any effect, but its more consistent with
how DBus arguments should be used.
After recent changes fixing wait_for_object_condition it was accidentally
made to only work with classes, not other types of objects. Instead
create a minimal class to hold _wait_timed_out so it doesnt rely on
'obj' holding the boolean.
The testAPRoam autotest was silently failing on my machine until I
realized that my distribution hostapd (Arch Linux) is not built with
CONFIG_WNM_AP=y. Indeed, it is also disabled by default in upstream
hostapd. This resulted in the send_bss_transition() function of
hostapd.py silently failing. With this change, throw an exception in
case the BSS_TM_REQ command does not succeed to hopefully save others
the time of debugging this problem.
There were some major problems related to logging and process
output. Tests which required output from start_process would
break if used with '--log/--verbose'. This is because we relied
on 'communicate' to retrieve the process output, but Popen does
not store process output when stdout/stderr are anything other
than PIPE.
Intead, in the case of logging or outfiles, we can simply read
from the file we just wrote to.
For an explicit --verbose application we must handle things
slightly different. A keyword argument was added to Process,
'need_out' which will ensure the process output is kept
regardless of --log or --verbose.
Now a user should be able to use --log/--verbose without any
tests failing.
After the re-write this was broken and not noticed until
recently. The issue appeared to be that the GLib timeout
callback retained no context of local variables. Previously
_wait_timed_out was set as a class variable, but this was
removed so multiple IWD instances could work. Without
_wait_timed_out being a class variable the GLib timeout
setting it had no effect on the wait loop.
To fix this we can set _wait_timed_out on the object being
passed in. This is preserved in the GLib timeout callback
and setting it gets honored in the wait loop.
Certain classes were still using the default namespace. This
didn't matter yet since testAP was the only test using namespaces,
and the AP interface was the only one being used.
For an IWD station on a separate namespace all objects need to
be accessable, so the namespace is passed along to those as needed.
When network namespaces are introduced there may be multiple
IWD class instances. This makes IWD.get_instance ambiguous
when namespaces are involved. iwd.py has been refactored to
not use IWD.get_instance, but testutil still needs it since
its purely based off interface names. Rather than remove it
and modify every test to pass the IWD object we can just
maintain the existing behavior for only the root namespace.
The agent path was generated based on the current time which
sometimes yielded duplicate paths if agents were created quickly
after one another. Instead a simple iterator removes any chance
of a duplicate path.