get_ordered_network() now scans automatically and has been updated
to use the StationDebug.Scan() API rather than doing a full
dbus scan (unless full_scan = True). The frequencies to be scanned
are picked automatically based on the current hostapd status
(hidden behind ctx.hostapd.get_frequency()).
There is a common block of code in nearly every test which is incorrect,
most likely a copy-paste from long ago. It goes something like:
wd.wait_for_object_condition(device, 'not obj.scanning')
device.scan()
wd.wait_for_object_condition(device, 'not obj.scanning')
network = device.get_ordered_network("ssid")
The problem here is that sometimes the scanning property does not get
updated fast enough before device.scan() returns, meaning get_ordered_network
comes up with nothing. Some tests pass scan_if_needed=True which 'fixes'
this but ends up re-scanning after the original scan finishes.
To put this to rest scan_if_needed is now defaulted to True, and no
explicit scan should be needed.
This will use the Roam() developer method to force a roam to
a certain BSS. This is particularly useful for any test requiring
roams that are not testing IWD's BSS selection logic. Rather than
creating hwsim rules, setting low RSSI values, and waiting for the
roam logic/scan to happen Roam() can be used to force the roam
logic immediately.
This is similar to wait_for_object_condition, but will not allow
any intermediate state changes between the initial and expected
conditions. This is useful for roaming tests when the expected
state change is 'connected' --> 'roaming' with no changes in
between.
After recent changes fixing wait_for_object_condition it was accidentally
made to only work with classes, not other types of objects. Instead
create a minimal class to hold _wait_timed_out so it doesnt rely on
'obj' holding the boolean.
After the re-write this was broken and not noticed until
recently. The issue appeared to be that the GLib timeout
callback retained no context of local variables. Previously
_wait_timed_out was set as a class variable, but this was
removed so multiple IWD instances could work. Without
_wait_timed_out being a class variable the GLib timeout
setting it had no effect on the wait loop.
To fix this we can set _wait_timed_out on the object being
passed in. This is preserved in the GLib timeout callback
and setting it gets honored in the wait loop.
Certain classes were still using the default namespace. This
didn't matter yet since testAP was the only test using namespaces,
and the AP interface was the only one being used.
For an IWD station on a separate namespace all objects need to
be accessable, so the namespace is passed along to those as needed.
When network namespaces are introduced there may be multiple
IWD class instances. This makes IWD.get_instance ambiguous
when namespaces are involved. iwd.py has been refactored to
not use IWD.get_instance, but testutil still needs it since
its purely based off interface names. Rather than remove it
and modify every test to pass the IWD object we can just
maintain the existing behavior for only the root namespace.
The agent path was generated based on the current time which
sometimes yielded duplicate paths if agents were created quickly
after one another. Instead a simple iterator removes any chance
of a duplicate path.
If the caller specifies the number of devices only return that many.
Some sub-tests may only need a subset of the total number of devices
for the test. If the number of devices expected is less than the total
being returned, python would throw an exception.
The host systems configuration directories for IWD/EAD were
being mounted in the virtual machine. This required that the
host create these directories before hand. Instead we can
just set up the system and IWD/EAD to use directories in /tmp
that we create when we start the VM. This avoids the need for
any host configuration.
This is somewhat of a hack, but the IWDDBusAbstract is a very
convenient abstraction to DBus objects. The only piece that restricts
it to IWD is the hardcoded IWD_SERVICE. Instead we can pass in a
keyword argument which defaults to IWD_SERVICE. That way other modules
(like EAD) can utilize this abstraction with their own service simply
by changing that service argument.
The AdHoc functionality in iwd.py was not consistent at all with
how all the other classes worked (my bad). Instead we can create
a very simple AdHocDevice class which inherits all the DBus magic
in the IWDDBusAbstract class.
Slower systems may not be able to make some timeouts that tests
mandated. All timeouts were increased significantly to allow tests
to pass on slow systems.
iwd.py was updated to use the TestContext APIs to start/stop
IWD. This makes the process managment consistent between starting
IWD from test-runner or from the IWD() constructor.
The psk agent is now tracked, and destroyed upon __del__. This is
to fix issues where a test throws an exception and never
unregisters the agent, causing future tests to fail.
The configuration directory was also chaged to /tmp by
default. This was done since all tests which used this used /tmp
anyways.
The GLib mainloop was removed, and instead put into test-runner
itself. Now any mainloop operations can use ctx.mainloop instead
There is a very common block of code inside many autotests
which goes something like:
device.scan()
condition = 'obj.scanning'
wd.wait_for_object_condition(device, condition)
condition = 'not obj.scanning'
wd.wait_for_object_condition(device, condition)
network = device.get_ordered_network('an-ssid')
When you see the same pattern in nearly all the tests this shows
we need a helper. Basic autotests which merely check that a
connection succeeded should not need to write the same code again
and again. This code ends up being copy-pasted which can lead to
bugs.
There is also a code pattern which attempts to get ordered
networks, and if this fails it scans and tries again. This, while
not optimal, does prevent unneeded scanning by first checking if
any networks already exist.
This patch solves both the code reuse issue as well as the recovery
if get_ordered_network(s) fails. A new optional parameter was
added to get_ordered_network(s) which is False by default. If True
get_ordered_network(s) will perform a scan if the initial call
yields no networks. Tests will now be able to simply call
get_ordered_network(s) without performing a scan before hand.
If no networks are found, return None rather than an empty
array. This is easier to check by the caller (and was assumed
in some cases). Also add an exception to get_ordered_network
if no network is found.
Initially the solution to copying files to .hotspot was to use the
existing copy_to_storage, but allow full directory copying. Doing it
this way does not allow us to copy single files into .hotspot which
makes it difficult to test single configurations in several consecutive
tests.
This adds a new API, copy_to_hotspot, where a single hotspot config
can be provided. clear_storage was also modified to clear out the
.hotspot directory in addition to the regular storage directory.
The start_ap method was raising potential dbus errors before converting
them to an IWD error type. This is due to dbus.Set() not taking an error
handler. The only way to address this is to catch the error, convert it
and raise the converted error.
For the interface connectivity tests obtain the lists of interfaces in
use directly from the IWD class, which has the current list from DBus
properties.
In the test utilties updated the wiphy_map struct built from the
TEST_WIPHY_LIST variable to parse the new format and to use a new
structure where each wiphy is a namedtuple and each interface under it
also contains a reference to that wiphy. The 'use' field is now
assigned to the wiphy instead of to the interface.
The AdHoc methods used to miss the change in properties
on AdHoc interface. To address the race condition, we
subscribe 'PropertiesChanged' signal first and then do
GetAll properties call. This way we are not missing
'PropertiesChanged' signal in between these calls.