This is a helper/shortcut to get_ordered_networks (plural). In nearly
all the autotests we had (roughly) the same block of code:
ordered_network = get_ordered_networks()[0]
self.assertNotEqual(ordered_network, None)
self.assertEqual(ordered_network.name, "someSsid")
Rather than having to do this, we can simplify and just have a single
call to get_ordered_network, which takes the SSID. If the SSID is not
found, we raise an exception. This avoids needing both asserts since
we are guarenteed that the return is valid and the SSID matches.
This also avoids possible issues with multiple networks showing up in
the GetOrderedNetworks call. Eventually test-runner will support running
tests on real wireless hardware, so its possible we could pick up
unexpected networks in the scan.
At some point a stray ';' got added into an autotest in a section
of code that is heavily copy pasted. So in turn nearly all the autotests
have this stray ';' after list_devices (and a few in other places).
testWPA was not verifying connectivity between the two interfaces. Funny
enough, doing this resulted in the same problems that adhoc had where
we were setting the connection as complete before the gtk/igtk were set.
This is fixed now so we can now use testutil in this test.
Curiously this test started failing. The problem was incorrect KC/SRES
values in the sim.db file. I noticed no direct changes to this file,
but changes inside ofono, phonesim, and hostapd could have potentially
caused this.
This test was copied from testFT-PSK-roam, but for SAE. The test behaves
as follows:
- Connect to SAE network (full authentication)
- Fast transition to another SAE AP
- Fast transition to a PSK/WPA2 AP
This is a temporary fix to address the recent split of
the Device interface. This patch contains a workaround that
re-enables the auto-tests while the test framework is being
reworked to satisfy the need of the new API and should not
be considered as a permanent solution.
Fixed two issues:
1. There is no longer a dbus exception when switching to AP mode when
connected in station mode so that assert was removed.
2. After the device/station change the timing must have changed, causing
autoconnect to take over before an explicit connect call. Added a
psk provisioning file that disables autoconnect.
Make sure stop_ap is called on success and on failure in both tests so
that one can succeed after the other has failed. Also make sure to move
both interfaces out of autoconnect state.
The default behavior of NetworkObject.connect() is to wait for the
Connect dbus method to reply before returning back to the test. This
change makes it possible to connect, but not wait for a reply and
continue on with the test (by specifying wait=False). This is
specifically required to test SAE anti-clogging, where the AP needs
to have several simultaneous connections at once for the anti-clogging
logic to trigger. This change also adds Device.wait_for_connected()
which waits for the device interface State variable to be "connected".