2017-05-20 01:39:39 +02:00
|
|
|
SignalLevelAgent hierarchy
|
|
|
|
==========================
|
|
|
|
|
|
|
|
Service unique name
|
|
|
|
Interface net.connman.iwd.SignalLevelAgent
|
|
|
|
Object path freely definable
|
|
|
|
|
|
|
|
Methods void Release(object device)
|
|
|
|
|
|
|
|
This method gets called when the service daemon
|
|
|
|
unregisters the agent. An agent can use it to do
|
|
|
|
cleanup tasks. There is no need to unregister the
|
|
|
|
agent, because when this method gets called it has
|
|
|
|
already been unregistered.
|
|
|
|
|
2018-08-14 03:30:54 +02:00
|
|
|
string Changed(object device, uint8 level)
|
2017-05-20 01:39:39 +02:00
|
|
|
|
|
|
|
This method gets called when the signal strength
|
|
|
|
measurement for the device's connected network
|
|
|
|
changes enough to go from one level to another out
|
|
|
|
of the N ranges defined by the array of (N-1)
|
|
|
|
threshold values passed to
|
|
|
|
net.connman.iwd.Device.RegisterSignalLevelAgent
|
|
|
|
(see device-api.txt.) The level parameter is in
|
|
|
|
the range from 0 to N, 0 being the strongest
|
|
|
|
signal or above the first threshold value in the
|
|
|
|
array, and N being the weakest and below the
|
|
|
|
last threshold value. For example if
|
|
|
|
RegisterSignalLevelAgent was called with the
|
|
|
|
array [-40, -50, -60], the 'level' parameter of
|
|
|
|
0 would mean signal is received at -40 or more dBm
|
|
|
|
and 3 would mean below -60 dBm and might correspond
|
|
|
|
to 1 out of 4 bars on a UI signal meter.
|