mirror of
https://github.com/42wim/matterbridge.git
synced 2024-12-01 16:59:29 +01:00
d16645c952
* Update mattermost library * Fix linting
413 lines
13 KiB
Go
413 lines
13 KiB
Go
// Copyright (c) HashiCorp, Inc.
|
|
// SPDX-License-Identifier: MIT
|
|
|
|
package hclog
|
|
|
|
import (
|
|
"io"
|
|
"log"
|
|
"os"
|
|
"strings"
|
|
"time"
|
|
)
|
|
|
|
var (
|
|
// DefaultOutput is used as the default log output.
|
|
DefaultOutput io.Writer = os.Stderr
|
|
|
|
// DefaultLevel is used as the default log level.
|
|
DefaultLevel = Info
|
|
)
|
|
|
|
// Level represents a log level.
|
|
type Level int32
|
|
|
|
const (
|
|
// NoLevel is a special level used to indicate that no level has been
|
|
// set and allow for a default to be used.
|
|
NoLevel Level = 0
|
|
|
|
// Trace is the most verbose level. Intended to be used for the tracing
|
|
// of actions in code, such as function enters/exits, etc.
|
|
Trace Level = 1
|
|
|
|
// Debug information for programmer low-level analysis.
|
|
Debug Level = 2
|
|
|
|
// Info information about steady state operations.
|
|
Info Level = 3
|
|
|
|
// Warn information about rare but handled events.
|
|
Warn Level = 4
|
|
|
|
// Error information about unrecoverable events.
|
|
Error Level = 5
|
|
|
|
// Off disables all logging output.
|
|
Off Level = 6
|
|
)
|
|
|
|
// Format is a simple convenience type for when formatting is required. When
|
|
// processing a value of this type, the logger automatically treats the first
|
|
// argument as a Printf formatting string and passes the rest as the values
|
|
// to be formatted. For example: L.Info(Fmt{"%d beans/day", beans}).
|
|
type Format []interface{}
|
|
|
|
// Fmt returns a Format type. This is a convenience function for creating a Format
|
|
// type.
|
|
func Fmt(str string, args ...interface{}) Format {
|
|
return append(Format{str}, args...)
|
|
}
|
|
|
|
// A simple shortcut to format numbers in hex when displayed with the normal
|
|
// text output. For example: L.Info("header value", Hex(17))
|
|
type Hex int
|
|
|
|
// A simple shortcut to format numbers in octal when displayed with the normal
|
|
// text output. For example: L.Info("perms", Octal(17))
|
|
type Octal int
|
|
|
|
// A simple shortcut to format numbers in binary when displayed with the normal
|
|
// text output. For example: L.Info("bits", Binary(17))
|
|
type Binary int
|
|
|
|
// A simple shortcut to format strings with Go quoting. Control and
|
|
// non-printable characters will be escaped with their backslash equivalents in
|
|
// output. Intended for untrusted or multiline strings which should be logged
|
|
// as concisely as possible.
|
|
type Quote string
|
|
|
|
// ColorOption expresses how the output should be colored, if at all.
|
|
type ColorOption uint8
|
|
|
|
const (
|
|
// ColorOff is the default coloration, and does not
|
|
// inject color codes into the io.Writer.
|
|
ColorOff ColorOption = iota
|
|
// AutoColor checks if the io.Writer is a tty,
|
|
// and if so enables coloring.
|
|
AutoColor
|
|
// ForceColor will enable coloring, regardless of whether
|
|
// the io.Writer is a tty or not.
|
|
ForceColor
|
|
)
|
|
|
|
// SupportsColor is an optional interface that can be implemented by the output
|
|
// value. If implemented and SupportsColor() returns true, then AutoColor will
|
|
// enable colorization.
|
|
type SupportsColor interface {
|
|
SupportsColor() bool
|
|
}
|
|
|
|
// LevelFromString returns a Level type for the named log level, or "NoLevel" if
|
|
// the level string is invalid. This facilitates setting the log level via
|
|
// config or environment variable by name in a predictable way.
|
|
func LevelFromString(levelStr string) Level {
|
|
// We don't care about case. Accept both "INFO" and "info".
|
|
levelStr = strings.ToLower(strings.TrimSpace(levelStr))
|
|
switch levelStr {
|
|
case "trace":
|
|
return Trace
|
|
case "debug":
|
|
return Debug
|
|
case "info":
|
|
return Info
|
|
case "warn":
|
|
return Warn
|
|
case "error":
|
|
return Error
|
|
case "off":
|
|
return Off
|
|
default:
|
|
return NoLevel
|
|
}
|
|
}
|
|
|
|
func (l Level) String() string {
|
|
switch l {
|
|
case Trace:
|
|
return "trace"
|
|
case Debug:
|
|
return "debug"
|
|
case Info:
|
|
return "info"
|
|
case Warn:
|
|
return "warn"
|
|
case Error:
|
|
return "error"
|
|
case NoLevel:
|
|
return "none"
|
|
case Off:
|
|
return "off"
|
|
default:
|
|
return "unknown"
|
|
}
|
|
}
|
|
|
|
// Logger describes the interface that must be implemented by all loggers.
|
|
type Logger interface {
|
|
// Args are alternating key, val pairs
|
|
// keys must be strings
|
|
// vals can be any type, but display is implementation specific
|
|
// Emit a message and key/value pairs at a provided log level
|
|
Log(level Level, msg string, args ...interface{})
|
|
|
|
// Emit a message and key/value pairs at the TRACE level
|
|
Trace(msg string, args ...interface{})
|
|
|
|
// Emit a message and key/value pairs at the DEBUG level
|
|
Debug(msg string, args ...interface{})
|
|
|
|
// Emit a message and key/value pairs at the INFO level
|
|
Info(msg string, args ...interface{})
|
|
|
|
// Emit a message and key/value pairs at the WARN level
|
|
Warn(msg string, args ...interface{})
|
|
|
|
// Emit a message and key/value pairs at the ERROR level
|
|
Error(msg string, args ...interface{})
|
|
|
|
// Indicate if TRACE logs would be emitted. This and the other Is* guards
|
|
// are used to elide expensive logging code based on the current level.
|
|
IsTrace() bool
|
|
|
|
// Indicate if DEBUG logs would be emitted. This and the other Is* guards
|
|
IsDebug() bool
|
|
|
|
// Indicate if INFO logs would be emitted. This and the other Is* guards
|
|
IsInfo() bool
|
|
|
|
// Indicate if WARN logs would be emitted. This and the other Is* guards
|
|
IsWarn() bool
|
|
|
|
// Indicate if ERROR logs would be emitted. This and the other Is* guards
|
|
IsError() bool
|
|
|
|
// ImpliedArgs returns With key/value pairs
|
|
ImpliedArgs() []interface{}
|
|
|
|
// Creates a sublogger that will always have the given key/value pairs
|
|
With(args ...interface{}) Logger
|
|
|
|
// Returns the Name of the logger
|
|
Name() string
|
|
|
|
// Create a logger that will prepend the name string on the front of all messages.
|
|
// If the logger already has a name, the new value will be appended to the current
|
|
// name. That way, a major subsystem can use this to decorate all it's own logs
|
|
// without losing context.
|
|
Named(name string) Logger
|
|
|
|
// Create a logger that will prepend the name string on the front of all messages.
|
|
// This sets the name of the logger to the value directly, unlike Named which honor
|
|
// the current name as well.
|
|
ResetNamed(name string) Logger
|
|
|
|
// Updates the level. This should affect all related loggers as well,
|
|
// unless they were created with IndependentLevels. If an
|
|
// implementation cannot update the level on the fly, it should no-op.
|
|
SetLevel(level Level)
|
|
|
|
// Returns the current level
|
|
GetLevel() Level
|
|
|
|
// Return a value that conforms to the stdlib log.Logger interface
|
|
StandardLogger(opts *StandardLoggerOptions) *log.Logger
|
|
|
|
// Return a value that conforms to io.Writer, which can be passed into log.SetOutput()
|
|
StandardWriter(opts *StandardLoggerOptions) io.Writer
|
|
}
|
|
|
|
// StandardLoggerOptions can be used to configure a new standard logger.
|
|
type StandardLoggerOptions struct {
|
|
// Indicate that some minimal parsing should be done on strings to try
|
|
// and detect their level and re-emit them.
|
|
// This supports the strings like [ERROR], [ERR] [TRACE], [WARN], [INFO],
|
|
// [DEBUG] and strip it off before reapplying it.
|
|
InferLevels bool
|
|
|
|
// Indicate that some minimal parsing should be done on strings to try
|
|
// and detect their level and re-emit them while ignoring possible
|
|
// timestamp values in the beginning of the string.
|
|
// This supports the strings like [ERROR], [ERR] [TRACE], [WARN], [INFO],
|
|
// [DEBUG] and strip it off before reapplying it.
|
|
// The timestamp detection may result in false positives and incomplete
|
|
// string outputs.
|
|
// InferLevelsWithTimestamp is only relevant if InferLevels is true.
|
|
InferLevelsWithTimestamp bool
|
|
|
|
// ForceLevel is used to force all output from the standard logger to be at
|
|
// the specified level. Similar to InferLevels, this will strip any level
|
|
// prefix contained in the logged string before applying the forced level.
|
|
// If set, this override InferLevels.
|
|
ForceLevel Level
|
|
}
|
|
|
|
type TimeFunction = func() time.Time
|
|
|
|
// LoggerOptions can be used to configure a new logger.
|
|
type LoggerOptions struct {
|
|
// Name of the subsystem to prefix logs with
|
|
Name string
|
|
|
|
// The threshold for the logger. Anything less severe is suppressed
|
|
Level Level
|
|
|
|
// Where to write the logs to. Defaults to os.Stderr if nil
|
|
Output io.Writer
|
|
|
|
// An optional Locker in case Output is shared. This can be a sync.Mutex or
|
|
// a NoopLocker if the caller wants control over output, e.g. for batching
|
|
// log lines.
|
|
Mutex Locker
|
|
|
|
// Control if the output should be in JSON.
|
|
JSONFormat bool
|
|
|
|
// Include file and line information in each log line
|
|
IncludeLocation bool
|
|
|
|
// AdditionalLocationOffset is the number of additional stack levels to skip
|
|
// when finding the file and line information for the log line
|
|
AdditionalLocationOffset int
|
|
|
|
// The time format to use instead of the default
|
|
TimeFormat string
|
|
|
|
// A function which is called to get the time object that is formatted using `TimeFormat`
|
|
TimeFn TimeFunction
|
|
|
|
// Control whether or not to display the time at all. This is required
|
|
// because setting TimeFormat to empty assumes the default format.
|
|
DisableTime bool
|
|
|
|
// Color the output. On Windows, colored logs are only available for io.Writers that
|
|
// are concretely instances of *os.File.
|
|
Color ColorOption
|
|
|
|
// Only color the header, not the body. This can help with readability of long messages.
|
|
ColorHeaderOnly bool
|
|
|
|
// Color the header and message body fields. This can help with readability
|
|
// of long messages with multiple fields.
|
|
ColorHeaderAndFields bool
|
|
|
|
// A function which is called with the log information and if it returns true the value
|
|
// should not be logged.
|
|
// This is useful when interacting with a system that you wish to suppress the log
|
|
// message for (because it's too noisy, etc)
|
|
Exclude func(level Level, msg string, args ...interface{}) bool
|
|
|
|
// IndependentLevels causes subloggers to be created with an independent
|
|
// copy of this logger's level. This means that using SetLevel on this
|
|
// logger will not affect any subloggers, and SetLevel on any subloggers
|
|
// will not affect the parent or sibling loggers.
|
|
IndependentLevels bool
|
|
|
|
// When set, changing the level of a logger effects only it's direct sub-loggers
|
|
// rather than all sub-loggers. For example:
|
|
// a := logger.Named("a")
|
|
// a.SetLevel(Error)
|
|
// b := a.Named("b")
|
|
// c := a.Named("c")
|
|
// b.GetLevel() => Error
|
|
// c.GetLevel() => Error
|
|
// b.SetLevel(Info)
|
|
// a.GetLevel() => Error
|
|
// b.GetLevel() => Info
|
|
// c.GetLevel() => Error
|
|
// a.SetLevel(Warn)
|
|
// a.GetLevel() => Warn
|
|
// b.GetLevel() => Warn
|
|
// c.GetLevel() => Warn
|
|
SyncParentLevel bool
|
|
|
|
// SubloggerHook registers a function that is called when a sublogger via
|
|
// Named, With, or ResetNamed is created. If defined, the function is passed
|
|
// the newly created Logger and the returned Logger is returned from the
|
|
// original function. This option allows customization via interception and
|
|
// wrapping of Logger instances.
|
|
SubloggerHook func(sub Logger) Logger
|
|
}
|
|
|
|
// InterceptLogger describes the interface for using a logger
|
|
// that can register different output sinks.
|
|
// This is useful for sending lower level log messages
|
|
// to a different output while keeping the root logger
|
|
// at a higher one.
|
|
type InterceptLogger interface {
|
|
// Logger is the root logger for an InterceptLogger
|
|
Logger
|
|
|
|
// RegisterSink adds a SinkAdapter to the InterceptLogger
|
|
RegisterSink(sink SinkAdapter)
|
|
|
|
// DeregisterSink removes a SinkAdapter from the InterceptLogger
|
|
DeregisterSink(sink SinkAdapter)
|
|
|
|
// Create a interceptlogger that will prepend the name string on the front of all messages.
|
|
// If the logger already has a name, the new value will be appended to the current
|
|
// name. That way, a major subsystem can use this to decorate all it's own logs
|
|
// without losing context.
|
|
NamedIntercept(name string) InterceptLogger
|
|
|
|
// Create a interceptlogger that will prepend the name string on the front of all messages.
|
|
// This sets the name of the logger to the value directly, unlike Named which honor
|
|
// the current name as well.
|
|
ResetNamedIntercept(name string) InterceptLogger
|
|
|
|
// Deprecated: use StandardLogger
|
|
StandardLoggerIntercept(opts *StandardLoggerOptions) *log.Logger
|
|
|
|
// Deprecated: use StandardWriter
|
|
StandardWriterIntercept(opts *StandardLoggerOptions) io.Writer
|
|
}
|
|
|
|
// SinkAdapter describes the interface that must be implemented
|
|
// in order to Register a new sink to an InterceptLogger
|
|
type SinkAdapter interface {
|
|
Accept(name string, level Level, msg string, args ...interface{})
|
|
}
|
|
|
|
// Flushable represents a method for flushing an output buffer. It can be used
|
|
// if Resetting the log to use a new output, in order to flush the writes to
|
|
// the existing output beforehand.
|
|
type Flushable interface {
|
|
Flush() error
|
|
}
|
|
|
|
// OutputResettable provides ways to swap the output in use at runtime
|
|
type OutputResettable interface {
|
|
// ResetOutput swaps the current output writer with the one given in the
|
|
// opts. Color options given in opts will be used for the new output.
|
|
ResetOutput(opts *LoggerOptions) error
|
|
|
|
// ResetOutputWithFlush swaps the current output writer with the one given
|
|
// in the opts, first calling Flush on the given Flushable. Color options
|
|
// given in opts will be used for the new output.
|
|
ResetOutputWithFlush(opts *LoggerOptions, flushable Flushable) error
|
|
}
|
|
|
|
// Locker is used for locking output. If not set when creating a logger, a
|
|
// sync.Mutex will be used internally.
|
|
type Locker interface {
|
|
// Lock is called when the output is going to be changed or written to
|
|
Lock()
|
|
|
|
// Unlock is called when the operation that called Lock() completes
|
|
Unlock()
|
|
}
|
|
|
|
// NoopLocker implements locker but does nothing. This is useful if the client
|
|
// wants tight control over locking, in order to provide grouping of log
|
|
// entries or other functionality.
|
|
type NoopLocker struct{}
|
|
|
|
// Lock does nothing
|
|
func (n NoopLocker) Lock() {}
|
|
|
|
// Unlock does nothing
|
|
func (n NoopLocker) Unlock() {}
|
|
|
|
var _ Locker = (*NoopLocker)(nil)
|